3. LFE → SUB ONLY (<120)
The LFE channel is reproduced up to 120 Hz in the subwoofer only. This is the norm for the movie industry.
4. LFE → SUB ONLY (WIDE)
The LFE channel is reproduced by the subwoofer only. There is no filtering of the LFE channel. This is an
appropriate setting when the input comes from the Sum output of another K+H subwoofer, or from
equipment with its own bass management, such a surround sound processor or DVD/Blue-ray disk player
(usually the "Subwoofer" output). Additionally, this mode is useful for detecting higher frequency signals
(up to 300 Hz) in the LFE channel that should otherwise be avoided.
The Remote Control and RS-232 EtherCon connector is used to connect hardware or RS-232 remote controlers to
the subwoofer. No audio passes down the CAT5 type cable, only control signals. The CAT-5 cable should not be
plugged into an IP or network output socket otherwise damage may occur to the source equipment. Furthermore,
the CAT cable should not carry an IP signal.
Operating Manual O 810 / O 870
All manuals and user guides at all-guides.com
LFE Channel Mode Settings
LFE Channel Electrical Response
English