Cuadro de averías motor Deutz
Código
Código
parpadeo
Diagnosis fault check to report the error to demand for an
636
555
ICO due to an error in the PoI3 efficiency factor
637
555
Internal ECU monitoring detection reported error
638
555
Monitoring of Fuel Quantity Correction
Diagnostic fault check to report the plausibility error in rail
639
555
pressure monitoring
Diagnostic fault check to report the error due to torque
640
555
comparison
Diagnosis of curr path limitation forced by ECU
641
555
monitoring level 2
Diagnosis of lead path limitation forced by ECU
642
555
monitoring level 2
Diagnosis of set path limitation forced by ECU
643
5-5-5
monitoring level 2.
644
5-5-5
Reported Over Voltage of Supply
646
5-5-5
Reported UnderVoltage of Supply
648
4-2-4
Manipulation control was triggered
649
4-2-4
Timeout error in Manipulation control
Early opening defect of main relay
654
7-5-7
No detail information!
DFC for stuck main relay error
656
7-5-7
No detail informationen!
Nox feed back fault detection
659
8-1-3
No detail informationen!
Plausibiliti error during Rich to Lean switch over
692
7-5-8
No detail informationen!
Monitoring of Nox signal readyness
693
7-5-8
No detail informationen!
Diagnostic fault check to report WDA active due to errors
714
5-5-5
in query-/response communication
Diagnostic fault check to report ABE active due to
715
5-5-5
undervoltage detection
Diagnostic fault check to report ABE active due to
716
5-5-5
overvoltage detection
Diagnostic fault check to report WDA/ABE active due to
717
5-5-5
unknown reason
Plausibility Check
720
2-1-1
No detail informationen!
732
2-2-4
Sensor error oil pressure; signal range check high
733
2-2-4
Sensor error oil pressure sensor; signal range check low
734
2-3-1
High oil pressure; warning threshold exceeded.
735
2-3-1
High oil pressure; shut off threshold exceeded
736
2-3-1
Low oil pressure; warning threshold exceeded
737
2-3-1
Low oil pressure; shut off threshold exceeded
743
1-4-4
Sensor error oil temperature; signal range check high
744
1-4-4
Sensor error oil temperature; signal range check low
745
1-4-4
High oil temperature; warning threshold exceeded
746
1-4-4
High oil temperature; shut off threshold exceeded
747
1-4-5
Override switch; plausibility error.
Sensor error airfilter differential pressure; short circuit to
750
1-3-6
battery
Sensor error airfilter differential pressure; short circuit to
751
1-3-6
ground
752
1-3-6
Air filter differential pressure; air filter cologged.
753
6-9-4
DPF burner air pump pressure sensor, plausibility error
DPF burner air pump pressure sensor, pressure above
755
6-9-4
upper shutoff threshold
DPF burner air pump pressure sensor, pressure below
758
6-9-4
lower shutoff threshold
DPF burner air pump pressure sensor, short circuit to
761
6-9-4
battery or open load
Descripción en Inglés
D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Código
Código
parpadeo
DPF burner air pump pressure sensor, short circuit to
762
6-9-4
ground
763
7-1-6
Exhaustgaspressure upstream burner, plausibility error
Exhaustgaspressure upstream burner, pressure above
765
7-1-6
upper shutoff threshold
Exhaustgaspressure upstream burner, short circuit to
770
7-1-6
battery or open load
Exhaustgaspressure upstream burner, short circuit to
771
7-1-6
ground
772
2-2-3
Pressure downstream charge air cooler, plausibility error
Pressure downstream charge air cooler, pressure below
774
2-2-3
lower physical threshold
Pressure downstream charge air cooler, short circuit to
776
2-2-3
battery or open load
Pressure downstream charge air cooler, short circuit to
777
2-2-3
ground
Boost pressure control; negative governor deviation
780
1-1-3
below limit
Learning valu too high
781
1-1-3
No detail informationen!
Over teperature of device driver of pressure control valve
785
1-1-3
No detail informationen!
Delta pressure across venturi in EGR line above physical
791
6-9-3
high limit
Plausibility Check fault for deviation of desired and actual
793
6-9-3
EGR-mass flow, where the latter is calculated out of EGR
Delta Pressure Sensor
Sensor error differential pressure Venturiunit (EGR), signal
795
6-9-3
range check low.
Sensor error differential pressure Venturiunit (EGR), signal
796
6-9-3
range check high.
Particulate filter regeneration.
Regeneration after time X is not successful (The error
805
8-4-5
occurs when the regeneration times (3x) over the max.
has been aborted allowed recovery time).
806
8-4-4
Particulate filter; regeneration not succesful
807
6-9-2
Differential pressure DPF, plausibility error
809
6-9-2
Differential pressure DPF maximum value is exceeded
Differential pressure sensor across DPF exceeds warning
810
6-9-2
high limit
Differential pressure DPF, pressure below lower shutoff
812
6-9-2
threshold.
Differential pressure DPF, pressure below lower warning
813
6-9-2
threshold.
Electrical error differential pressure B58 (DPF). (signal
814
6-9-2
range check high)
Electrical error differential pressure (DPF). signal range
815
6-9-2
check low.
The pressure relief valve (PRV) has reached the number
825
2-5-3
of allowed activations.
Pressure relief valve is forced to open, perform pressure
826
1-4-6
increase.
Pressure Relief Valve (PRV) forced to open. Performed by
827
1-4-6
pressure increase.
Pressure Relief Valve (PRV) forced to open. Shutoff
828
1-4-6
conditions.
Pressure Relief Valve (PRV) forced to open. Warning
829
1-4-6
conditions.
830
1-4-6
Open Pressure Relief Valve (PRV)
Pressure Relief Valve (PRV) error; Rail pressure out of
831
1-4-6
tolerance range.
Rail pressure out of tolerance range. The PRV can not be
832
1-4-6
opened at this operating point with a pressure shock.
Descripción en Inglés