76
Cuadro de averías motor Deutz
Código
Código
parpadeo
975
5-5-5
Softwarereset CPU SWReset_2
Plausibility error between APP1 and APP2 or APP1 and
976
2-2-6
idle switch.
Plausibility error between sensor and idle switch,
Acceleratio
978
1-2-6
Pedal Detection. In case of Hand Throttle with Low Idle
Switch, it is the plausibility check between hand throttle
and idle switch.
980
5-1-5
Terminal 50 was operated too long
Air flow temperature sensor; short circuit to battery or
981
2-2-6
open load.
982
2-2-6
Air flow temperature sensor; short circuit to ground
Burner temperature, temperature above upper shutoff
986
7-1-4
threshold
Burner temperature, temperature below lower shutoff
989
7-1-4
threshold
Charged Air cooler down stream temperature.
992
1-2-8
Temperature below lower physical threshold.
Electrical error charged air temperature. Signal range
994
1-2-8
check high.(SRC)
Electrical error charged air temperature. Signal range
995
1-2-8
check low.
Charged air cooler temperature. System reaction initiated.
996
2-3-3
High charged air cooler temperature. Warning threshold
exceeded.
High charged air cooler temperature. Shut off threshold
997
2-3-3
exceeded.
Diagnostic fault check for charged air cooler downstream
998
1-2-8
temperature sensor
No detail informationen!
Electrical error EGR cooler downstream temperature.
1007
6-8-2
Signal range check high.
electrical error EGR cooler downstream temperature.
1008
6-8-2
Signal range check low.
Physical range check high for EGR cooler downstream
1011
7-7-1
temperature.
Physical range check low for EGR cooler downstream
1012
7-7-1
temperature.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve
1014
5-9-4
(4.1;6.1;7.8).
Signal range check high.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve
1015
5-9-4
(4.1;6.1;7.8).
Signal range check low.
Actuator position for EGR-Valve (2.9;3.6) or Throttle-Valve
1016
5-9-4
(4.1;6.1;7.8) not plausible.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve
1022
5-9-4
(4.1;6.1;7.8).
Signal range check high
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve
1023
5-9-4
(4.1;6.1;7.8).
Signal range check low
Position sensor error of actuator EGR-Valve (2.9;3.6) or
1024
5-9-4
Throttle-Valve (4.1;6.1;7.8).
Signal range check high.
Position sensor error actuator EGR-Valve (2.9;3.6) or
1025
5-9-4
Throttle-Valve (4.1;6.1;7.8).
Signal range check low.
1026
6-8-4
Temperature downstream DOC, plausibility error
Temperature downstream DOC, temperature above upper
1029
6-8-4
shutoff threshold
Temperature downstream DOC, temperature above upper
1030
6-8-4
warning threshold
Descripción en Inglés
D 600 AP / D 600 AP PLUS / D 600 APG / D 600 APG PLUS
Código
Código
parpadeo
Sensor error exhaust gas temperature downstream
1034
6-8-4
(DOC); signal range check high
Sensor error exhaust gas temperature downstream
1035
6-8-4
(DOC); signal range check low
1036
6-8-3
Temperature upstream DOC, plausibility error
Temperature upstream DOC, temperature above upper
1039
6-8-3
shutoff threshold
Temperature upstream DOC, temperature above upper
1040
6-8-3
warning threshold
Electrical error exhaust gas temperature upstream (DOC);
1044
6-8-3
signal range check high
Electrical error exhaust gas temperature upstream (DOC);
1045
6-8-3
signal range check low
Sensor error particle filter downstream temperature; signal
1047
6-8-5
range check low
Sensor error exhaust gas temperature upstream turbine;
1067
5-5-6
signal range check high
Exhaust temperature upstream SCR-Cat, temperature
1069
6-6-8
above upper physical threshold
Sensed exhaust temperature before SCR-Cat is <
1070
6-6-8
physical low limit
Signal error for CAN message
1071
6-6-8
No detail informationen!
Sensor error DEF catalyst exhaust gas temperature
1072
6-6-8
upstream; signal range check high
Sensor error DEF catalyst exhaust gas temperature
1073
6-6-8
upstream; signal range check low
1074
1-2-7
DEF tank level; warning threshold exceeded
1075
6-7-7
DEF dosing valve; power at the end of injection too high
1077
6-7-7
DEF dosing valve; short circuit to battery on low side
DEF dosing valve; short circuit to battery or open load
1078
6-7-7
on hig side
Urea dosing valve; short circuit to ground or open load
1079
6-7-7
on low side
1080
6-7-7
DEF dosing valve; short circuit on high side
SCR heater relay DEF returnline sekondary side; open
1081
6-7-4
load
1082
7-6-2
SCR main relay (secondary side): open load
SCR heater relay DEF pressureline secondary side; open
1083
6-7-3
load
1084
7-6-2
SCR main relay (secondary side); Shortcut to battery
SCR main relay (secondary side), heat relay (secondary
1085
7-6-2
side), heating elements or heating valve short to ground.
SCR heater relay DEF supplyline secondary side; open
1086
6-7-5
load
SCR heater relay DEF supply modul secondary side;
1087
6-7-2
open load
1088
6-7-1
SCR Tank heating valve secundary side: open load
SCR heater; Pressure line heater error and temperature
condition to perform an afterrun (Group error diagnosis
1089
7-8-3
heater)
SCR system heater diagnostic reports error; shut off
SCR-system
1090
6-7-4
SCR heater relay DEF returnline primary side; open load
1092
6-7-4
SCR heater DEF returnline; short circuit to battery
1093
6-7-4
SCR heater DEF returnline; short circuit to ground
SCR heater relay DEF pressureline primary side; open
1094
6-7-3
load
1096
6-7-3
SCR heater DEF pressureline; short circuit to battery
1097
6-7-3
SCR heater DEF pressureline; short circuit to ground
1098
6-7-6
tank heating valve; open load
Descripción en Inglés