3
MAINTENANCE
3.1
Periodic maintenance
Periodic maintenance, as well as being necessary for the optimal functioning of the burner and the plant, is required by Law and if
maintenance regulations are not observed, there can be problems or even fines.
Maintenance must be entrusted to and carried out SOLELY by qualified technicians.
The pellet burner B-Home Round 25 (code 8075980) and B-Essential Round 50 (code 8075981) was designed to require mini-
mal maintenance, the frequency of which depends directly on the quality and size of the pellets used (certified or not) and on
adjustments made to the settings.
WARNING DANGER ELECTRICITY
Before carrying out any maintenance activity, disconnect the appliance from the mains, and put the general switches on the plant
into the OFF position, but also the main ones on the burner and the boiler (if present).
WARNING CAUTION
– When carrying our maintenance, all the Personal Safety Equipment required by current Legislation must be used.
– Periodic maintenance refers to the whole plant in which the burner is installed.
– If non-certified pellets are used, the indications below are rendered null and void, since the characteristics of the fuel are not
known.
– In the event of the use of non-certified pellets, Fonderie Sime S.p.A. DOES NOT ACCEPT RESPONSIBILITY for any breakages or
malfunctions or for any possible harm to people, animals or things, or to the environment.
– The table is only for suggestion purposes and is not binding.
– For cleaning the housing of the burner, use a damp cloth with water and soap or water and methylated spirits, or with specific
non-abrasive products.
Periodic
BURNER CLEANING
Combustion chamber - ash and slag
Burner fan
Internal cochlea
Photocell
Ignition resistance
Pellet container
Combustion air suction grill
External cochlea bearings
Possible greasing or lubrication
External cochlea fan
Control of perishable parts
Control of cables and
electrical connections
PLANT CLEANING
Smoke channel and flue pipe
Inside and back part of the boiler
Control of perishable parts
Control of exhaust fumes
38
When necessary
Weekly
Filling
Six-monthly
x
x
x
x
x
x
x
x
x
x
x
Annual
x
x
x
x
x
x
x
x
x
x
x
x
x