2.0 EN: Installation Sheet
Product description
The Premier Elite AMQD/AMDT are designed to detect movement of an intruder
and activate an alarm control panel. The product is intended to be connected to a
listed burglar compatible control unit or a power supply that has a voltage output
range of between 9 to 15 VDC and provides a minimum of 4 hours of standby
power.
1. Installation guidelines
The technology used in these detectors resists false alarm hazards. However,
avoid potential causes of instability such as
Avoid mounting the detector where objects may interfere with the anti-
masking function (<1m), above doors, near curtains etc.
The detector should not be mounted in direct sunlight.
Not suitable for outdoor use.
2. Opening the detector
Unwind the screw at the base of the detector until loose; the screw will be
retained in the product
Lift detector lid out from the base and off the lugs at the top
2).
3. Mounting the detector
Rear tamper pull-out needs to be secured to the mounting surface to meet Grade 3
requirements
(see Fig. 3,
4. Premier Elite AMDT
5. Premier Elite AMQD
Set the mounting height by adjusting the position of the PCB.
Wire the detector.
Select the desired jumper settings.
INS542-5 14/52
(see Fig. 2,
step1).
step1).
(see Fig.
1).
(see Fig. 2, step