BFT ZARA BTL2 Instrucciones De Instalación página 12

Ocultar thumbs Ver también para ZARA BTL2:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
DIP
Logic
4
Edge input check
Photocells
5
during closing
6
Fast closing
Block pulses
7
during opening
8
3-step logic
Safety edge input
6
operation
7
Fast closing
Residential /
apartment
8
building
operation
Hammer during
9
opening
Closing limit
10
switch pressure
12
- ZARA BTL2
INSTALLATION MANUAL
Cross out
Default
setting used
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
Description
Enable safety check on the BAR input
Safety check on BAR input not enabled
In the event beam is broken, photocell operation is disabled during opening. During closing,
movement is reversed immediately.
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
Only active on FW < 2.05
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Logic not enabled
The start pulse has no effect during opening.
The start pulse has effect during opening.
Switches to 3-step logic; during closing, start
reverses movement.
Switches to 4-step logic.
Only active on FW ≥ 2.05
Safety edge with active reversal only when closing, when opening the movement stops
Safety edge with active reversal in both directions
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Logic not enabled
Sets the automation type of operation:
ON = Apartment building
OFF = Residential
Reaction to the START input (wired or radio):
Residential
CLOSED
Opens
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens
Reaction to the OPEN input (wired):
Residential
CLOSED
Opens
WHILE CLOSING
Opens
OPEN
No effect
WHILE OPENING
Keeps it open
AFTER STOP
Opens
Reaction to the PEDESTRIAN input (radio):
Residential
CLOSED
Opens partially
WHILE CLOSING
Stops
OPEN
Closes
WHILE OPENING
STOPS + TCA
AFTER STOP
Opens partially
All firmware
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows
the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of
the closing limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop
sensor interpreting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or
as far as the mechanical stop. In this way, the leaves come to rest perfectly against the stop
by allowing the closing limit switches to trip slightly earlier (Fig.G Ref.A).
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
Apartment building
Opens
Opens
Closes
No effect
Opens
Apartment building
Opens
Opens
No effect
Keeps it open
Opens
Apartment building
Opens partially
Opens partially
Closes
No effect
Opens partially
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens