GB
Fold out pages:
Please pass these instructions on to the fitting user!
Safety notes
Prevention of frost damage
When the domestic water system is drained, the thermostats
must be drained separately since non-return valves are
installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Application
Infrared fittings with thermostat are designed for hot water
supply via pressurised storage heaters and, utilised in this
way, provide the best temperature accuracy. With sufficient
power output (from 18 kW or 250 kcal/min), electric or gas
instantaneous heaters are also suitable.
Thermostats cannot be used in connection with unpressurised
storage heaters.
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see "Adjusting").
Technical data
• Minimum flow pressure
• Operating pressure
• Recommended flow pressure
• Test pressure
If static pressure exceeds 5 bar, a pressure-reducing valve
must be fitted.
• Flow rate at 3 bar flow pressure:
• Minimum flow rate
• Temperature at hot water supply:
Recommended (energy saving):
• Hot water end stop
• Hot water temperature at supply connection min. 2 °C higher
than mixed water temperature
• Voltage supply:
• Battery check
• Automatic safety shut-off (factory setting):
• Automatic flushing (factory setting: deactivated)
• Reception range with Kodak Gray Card,
grey side, 8 x 10", landscape (factory settings):
- Start / stop water flow:
- Automatically stop water flow:
• Run-on time (factory setting):
• Type of protection:
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature for ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
Special accessories
• Infrared remote control (Prod. no.: 36 206) for changing the
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly!
Install S-unions and screw-mount the fitting
Refer to the dimensional drawings on fold-out page I.
The cold water supply must be connected on the right, hot
water supply on the left.
1. Install S-unions (A) and attach the sleeve preassembled
2. Insert filters (C) and screw-mount the fitting.
3. Push the sleeve with escutcheon onto the union nut.
4. Screw the escutcheon flush against the wall.
1 bar
max. 10 bar
Install spout, see Fig. [2].
1 - 5 bar
A 130° swivel limiter is prefitted in the spout. To lock the spout,
10 bar
proceed as follows:
1. Detach O-rings (D), see Fig. [3].
2. Lift off lug washer (E), rotate through 180° and reinsert.
Approx. 9 l/min
3. Fit O-rings (D) and install the spout.
5 l/min
max. 70 °C
Open cold and hot-water supply and check connections
60 °C
for water-tightness.
35 °C - 45 °C
Reversed connection (hot on right - cold on left):.
Replace thermostatic cartridge 47 217, see fold-out page I,
6 V-lithium battery (type CR-P2)
Prod. no.: 47 657.
Flashing signal
60 s
Operation
The infrared electronics are set as follows at the factory:
3 - 7cm
Start water flow
> 35cm
Hold the hand at a distance of 3 - 7cm in front of the sensor
1 s
system (F), see Fig. [4].
IP 69 K
Stop water flow
• 1 s after leaving the detection zone.
A
• On approaching with the hand again.
2
The range of the sensor system is dependent upon the
2500 V
reflective properties of the detected object.
100 °C
Note:
As operating instructions, we recommend affixing the enclosed
sticker in public areas.
factory settings.
This product conforms to the requirements of the
relevant EU guidelines.
with escutcheon (B), see Fig. [1].
4