of a problem please check all shown possibilities and follow below instructions before y
contact an after sales service. See CUSTOMER SERVICE.
WARNING!
Before maintenance, deactivate the appliance and disconnect the mains plug from
the mains socket.
improper repairs can cause considerable consequential damages.
A damaged supply should only be replaced by the manufacturer, its service agent or
Error Code
Low temperature alarm when the
L2
temperature of the control sensor
is too low;
When the temperature of the con-
H1
trol sensor is too high, the high te-
mperature alarm will be displayed
on the display screen;
Cause
Solution
1.Check the ambient temperature .
2.Check the Compressor connec-
tor.
3.Check the resistance of the tem-
perature control sensor.
1.Check the connector of the cont-
rol board or the display panel.
2.Check the resistance and the vol-
tage of the fan.
3.Check the fan and the compres-
sor connector.