Descargar Imprimir esta página

Factory Settings; Mounting And Installation; Installation References - hafele EFL 30 Manual De Instrucciones

Ocultar thumbs Ver también para EFL 30:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 100

3.4 Factory settings

Parameter
Open time (duration of unlocking period in latchbolt lock operation)
• The open time can be set to up to 30 seconds at one second intervals
in stand-alone operation
deadbolt lock operation, page 55.
• The open time can be extended to beyond 30 seconds using a macro
with the MDU 110 mobile programming unit with special functions.
Lock type

4. Mounting and installation

The installation instructions for the product can be found in a separate document. They can be
accessed via the QR code on the enclosed information sheet or under the respective
catalogue number at www.hafele.com.
Please pay attention to the following points when installing the product:
The environmental conditions in the place of installation – for example, magnetic fields
or metal materials – may impair the functionality of the product.
• Ensure that the product is installed in a suitable location.
Observe the maximum material thickness of the installation surfaces to ensure the
reading range of the transponders
• Avoid glass, mirrors or metallic/coated installation surfaces.
• Set up a sample installation in the chosen location and test it out prior to carrying
out the final installation.
Do not insert the batteries once the assembly and installation work is complete. This
step should not be completed before commissioning the product. The drawers may
need to be removed again for drawer assembly.
• Once the batteries have been inserted, the product commissioning process
launches automatically.
• Read chapter
first time.

4.1 Installation references

• Ensure that the EFL 30 / EFL 30 C is not installed next to power lines. The magnetic field of
the power lines can impair the antenna range.
• Recommendation: carry out a trial mounting attempt before installing the EFL 30 / EFL 30 C.
• Do not mount the locking component of the EFL 30 / EFL 30 C until it is in the place of
installation.
• Only adjust the EFL 30 / EFL 30 C at the installation location and readjust if necessary after
loading the furniture item.
• Ensure that there are no metal panels mounted between the locking component and the
EFL 30 / EFL 30 C.
• The locking component of the EFL 30 / EFL 30 C can be screwed on with a furniture handle
(hole spacing 32 mm) on the opposite side.
8.3 Set open time / set permanent
5. Commissioning, page 44 before inserting the batteries for the
Value
3 s
Latchbolt lock operation
EFL 30 / EFL 30 C
.
43

Publicidad

Solución de problemas

loading

Este manual también es adecuado para:

Efl 30c