Descargar Imprimir esta página

Set Unit Upright; Set Up Drain Hose; Plug In Electrical Cord - Uline H-10029 Manual De Instrucciones

Ocultar thumbs Ver también para H-10029:

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: The most accurate way to monitor
temperature is with a thermo-hygrometer;
however, an indoor/outdoor thermometer can
also be used to measure temperature. Position
thermometer in the center of the room away
from the airflow of the dehumidifier.

SET UNIT UPRIGHT

Always operate the dehumidifier in an upright position.
(See Figure 1)
NOTE: If the unit has been stored or transported
in a horizontal position, set it upright (vertical)
for at least 30 minutes before operating it.
When the unit is stored horizontally, oil from
the compressor flows into the refrigerant coils,
reducing the ability of the dehumidifier to
function.

SET UP DRAIN HOSE

The condensate pump connects to a plastic drainage
hose that is wrapped around the air outlet located
at the back of the unit. Unwrap the entire hose and
place the unattached end in a sink, drain, bucket or
outside – anywhere that water can drain out safely. If
using a bucket or other receptacle for water collection,
check it regularly to prevent spills.
NOTE: Uncoil and straighten the entire drain
hose. Do not leave any part of the hose coiled
on the unit and do not place the end of the
hose higher than 20 feet above the top of the
unit. Check for kinks or obstructions that would
restrict the flow of water. Failure to do so may
cause a water backup in the pump, resulting
in leakage.
PAGE 2 OF 18
INSTALLATION CONTINUED
OPERATION

PLUG IN ELECTRICAL CORD

Locate the electrical cord either on the top or
back of the unit. Unit may be plugged in to a 115-volt
(15 amp) grounded outlet, which is standard in most
homes.
NOTE: If the temperature rises to unsafe levels
(over 90°F), use the structure's HVAC (heating/air
conditioning) system to bring the temperature
down. Set it to 80°F and continue to operate
the dehumidifier.
Figure 1
Processed
(Dehumidified)
Air Outlet
NOTE: If the unit experiences a loss of power,
either from a power interruption or from
thermal overload protection, let the unit rest
for five minutes before restarting. Otherwise, it
might shut off again.
Control
Panel
Molded Indent
for Power Cord
Storage
Humid Air Inlet
(Air Filter Located
Behind Screen)
0422 IH-10029

Publicidad

loading