Descargar Imprimir esta página

User Enrolment In 1:N Mode; User Enrolment In 1:1 Mode - Fermax AC-MAX Manual De Instalación

Ocultar thumbs Ver también para AC-MAX:

Publicidad

Idiomas disponibles

Idiomas disponibles

Cod. 970077
V08_19
2. In the opened window select
previously configured with AC-MAX HW including IP address, port and communication
password.
3. Verify settings with

4.3 User enrolment in 1:N mode

In 1:N mode, user enrolment including fingerprint scanning and assignment of access rights is done
in AC-MAX software. It is recommended to use wizards for user management. In order to add new
Wizard
user select
command in the top menu of AC-MAX software, then
and proceed according to following guidelines:
Authentication Factors
1. In
instead of default
2. Select finger for scanning and then
3. Select FPAC-MAX FINGERPRINT reader for scanning and then
4. Proceed according to displayed messages.
Add Person Online wizard
5. Return to
6. When wizard is closed, additionally configure AC-MAX FINGERPRINT reader(s) selecting
Synchronisation
opened window select readers and click

4.4 User enrolment in 1:1 mode

In 1:1 mode Mifare cards can be programmed with fingerprint templates only within AC-MAX HW
software according to following procedure:
1. After establishing connection with FPAC-MAX FINGERPRINT reader in the top menu of AC-MAX
HW software select
Format
2. Click
button and place Mifare card in vicinity of reader for approximately 10 sec. until
Card formatted successfully
3. Select
Fingerprint template
4. Proceed according to displayed messages.
5. In AC-MAX software enrol user with Add Person Online wizard assigning card number with
previously programmed fingerprint template.
6. Upload settings to controller.
Note: In 1:1 mode do not define FPAC-MAX FINGERPRINT reader in AC-MAX software and do not
assign users with any fingerprint templates in AC-MAX software.
Table 5. Maximal number of fingerprint templates on Mifare cards
Card
Ultralight
Classic 1k
All manuals and user guides at all-guides.com
Add
button and enter communication parameters which were
Test connection
button.
window when new factor is added select
40bit proximity card
.
Read from Reader
and upload configuration to the controller in the last step.
command in top right corner of AC-MAX and then
Start
Card Programmer
command and then
message is displayed.
tab and then
Save template
Max. number of templates
0
1
Add Person Online
Fingerpint
button.
Scan
button.
button.
Card formatting
button in order to start wizard.
wizard
Type
in the field
Synchronize
icon. In the
tab.
24/26

Publicidad

loading