Fronius Inverter
Installation
61
Inside
1
3
Conduit
Seal all used conduits!
Seal every incoming and every outgoing conduit!
Conduit
Seal both conduit ends!
Application example
Fronius Inverter
Operating
Instructions
*
+
* Serial Number Sticker for Customer Use, 57 x 20 mm
**
** DRMs for
2
*
Australia
for Customer Use, 67 x 20 mm
62
Outside
DC=
Conduit
AC~
Air circulation
Condensation
NOTE! Condensation within the conduits
can damage the inverter or components of
the photovoltaic systems.
To avoid undesirable air circulation and
condensation in the conduits,
– seal all conduits being used with a per-
manently elastic sealant,
– seal every incoming and outgoing con-
duit,
– seal both conduit ends.