Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Operating Manual SATAjet 4600 B RP/HVLP
EN
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be pressurised with clean compressed air
during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine right
after the cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle set and gun surface!
• After cleaning, the spray gun, the material passages, the air cap
including thread as well as the gravity flow cup have to be blown
dry with clean compressed air!*
* otherwise risk of corrosion
• Check spray pattern after cleaning the nozzle set!
• Further tips concerning cleaning can be found at www.sata.com/TV.

9. Maintenance

• Prior to maintenance, disconnect the spray gun from the compressed air
circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
9.1. Replacing the nozzle set
and [7-6]
Every SATA nozzle set consists of "paint needle" [7-1], "air cap" [7-2]
and "fluid tip" [7-3] and has been hand-adjusted to provide a perfect
spray pattern. Lubricate both paint needle [7-1] in the paint needle area
(approx. 3 cm in front of the needle sleeve, paint needle spring) and ma-
terial flow control screw [1-11]. Therefore, always exchange the com-
42
Warning! Attention!
Note!
Warning! Attention!
[7-1], [7-2], [7-3], [7-4], [7-5]

Publicidad

Solución de problemas

loading