Descargar Imprimir esta página

gsc evolution 200205056 Manual Del Usuario página 13

Ocultar thumbs Ver también para 200205056:

Publicidad

Idiomas disponibles

Idiomas disponibles

INTRODUCTION
Thank you for the purchase of our quality product. Used carefully and in accordance with the instructions set
out below. Please read and keep these instructions for future reference.
FEATURES
Type: Recessed
Dimmable: In time and light
Power: 15W (1100Lm)
Area detection: 140°
Ambient light: <3-2000Lux (dimmable)
Working temperature: -20°±40°C
Working Humidity: <93%RH
Detection distance: Max. 9 meters (>24°)
Installation height: 1.8M-2.5M.
Time delay: Min. 10sec. ± 3sec. to 5min. ± 1min.
Power consumption: 1.2W
Detection motion speed: 0.6-1.5M/S
Voltage: 220-240V/AC
Hz: 50/60Hz
IP54
With emergency light
Continuous ilumination time: 5 hours.
Lithium battery 3.7V/1500mAh
Color temperature: 6000K
UNIT POSITIONING
To ensure correct operation of the detector take
into account the following specifications:
- The detector is designed for optimal operation
when placed between 1.8M and 2.5M on the wall
or 9M from the ground level.
- Rain, snow and wind storms can create sudden
temperature changes that can make connecting
the detector. To minimize this risk is convenient to
install in a protected area.
- Avoid placing the detector near air temperatu-
re alteration zones such as air condition, central
heating, etc... It can cause the device to trip for
no real reason.
- Avoid point to lights and reflective areas.
- Avoid placing the sensor near areas of elec-
tromagnetic disturbance. It can also cause false
alarms.
- The detector is more sensitive to movement
across the width of the detection zone and less
sensitive far the more is the appliance.
FUNCTION
The product is an energy-saving automatic sensor
lamp, adopting integrated circuit and precise detecting
components. It gathers automatism, convenience,
safety, saving-energy and practical functions. It can
identify day and night. The lamp can turn on when one
enters detection field and can turn off automatically
when one leaves detection field.
- The lamp can working state in different ambient
light. It can work in the daytime and at night when it is
adjusted on the "Sun" position (Max.). It can work in
the ambient light less than 3Lux when it is adjusted on
the "Moon" position (Min.).
- The length of time delay could be set according to
the customers's requirement, the minimum time of
this item is 10sec ± 3sec, and the maximum is 5min
± 1min.
INSTALLATION
- Switch off the power.
- Screw off the nail on the bottom of sensor lamp and
unload the bottom. (Image 1/Page 4)
- Pass the wire through the hole in the bottom and
connect the power wire into connection-wire column.
(Image 2/Page 4)
- Install the sensor lamp in the position where you
need with inflated screws. (Image 3/Page 4)
- Switch on the power and test it.
TEST
Turn the time knob anti-clockwise on the minimum.
Turn the "LUX" knob clockwise on the maximum (Sun).
Switch on the power; the lamp will have no signal at
the beginning. After warm-up 30 seconds, the lamp
can strat work. If it receives the induction signal, the
lamp will turn on. While there is no another induction
signal any more, the lamp should stop working within
10 ± 3 seconds.
Turn "LUX" knob anti-clockwise on the minimum
(Moon). If the ambient light is more than 3Lux, the lamp
should not work. If the ambient light is less than 3Lux
(Darkness), the sensor would work. Under no induction
signal condition, the lamp should stop working within
10 ± 3 seconds.
Note: when testing in daylight, please turn "LUX"
knob to (Sun) position, otherwise the sensor lamp
could not work.
EN
www.garsaco.com | 13

Publicidad

loading