Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

P r i m i n g
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full
stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of the trigger.
O i l D e t a i l s
The recommended oil for priming is Hyspin VG32 and AWS 32 available in 0.5l (part number 07992-00002) or one gallon containers
(part number 07992-00006). Please see safety data below.
H y s p i n V G 3 2 a n d A W S 3 2 O i l S a f e t y D a t a
First Aid
SKIN:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. Short term contact
requires no immediate attention.
INGESTION:
Seek medical attention immediately. DO NOT induce vomiting.
EYES:
Irrigate immediately with water for several minutes. Although NOT a primary irritant, minor irritation may occur following contact.
Fire
Suitable extinguishing media: CO
Environment
WASTE DISPOSAL: Through authorised contractor to a licensed site. May be incinerated. Used product may be sent for reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses. Soak up with absorbent material.
Handling
Wear eye protection, impervious gloves (e.g. of PVC) and a plastic apron. Use in well ventilated area.
Storage
No special precautions.
P r i m i n g P ro c e d u r e
DO NOT OPERATE THE TRIGGER WHILE THE BLEED SCREW IS REMOVED
All operations should be carried out on a clean bench, with clean hands in a clean area.
Ensure that the new oil is perfectly clean and free from air bubbles.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
Remove Screw 2 and Seal 1 from Plastic Cover plate 4 on the intensifier reservoir.
Pour the priming oil into the reservoir until it is approximately
Replace Screw 2 and Seal 1.
Connect the intensifier unit to the air supply. Remove screw from reservoir.
With the pistol unit fitted to the intensifier unit and held below the level of the intensifier unit, unscrew Bleed Screw 58 from Bleed
Plug Assembly 2 on the 07530 Mk II tool or Bleed Screw 66 from Bleed Plug Assembly 30 on the 07532 Mk II tool two turns and
allow oil to flow out of the tool.
When the oil runs freely and free of air bubbles, tighten the bleed screw.
Top up the reservoir on the intensifier unit with priming oil.
Cycle the tool until any air bubbles present in the oil are expelled into the oil reservoir.
Item numbers in bold refer to the general assemblies and parts lists pages 28-33.
36
, dry powder, foam or water fog. DO NOT use water jets.
2
I M P O R T A N T
1
/
" (12mm) from the top.
2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

7530-07532

Tabla de contenido