NOTE: You may need a helper to align and secure the
diverter.
Screw the mounting nut onto the diverter valve body as far
down as it will go; slip the friction washer and rubber
washer over the nut. Locate the diverter valve body up
through the deck/rim or wall. Set the washer and
escutcheon on the diverter valve body. Loosely thread the
escutcheon down onto the diverter valve body to hold the
diverter in place.
Continue to thread the escutcheon onto the diverter valve
body until the top of the escutcheon is flush with the valve
body. This will allow clearance for proper handle function.
Align the inlets and outlets. Hand tighten the mounting
nut.
B. SOLDER CONNECTIONS
CAUTION: Risk of product damage. Internal
cartridge assembly should still be removed.
Dry fit all piping and connectors.
Solder piping for optional spout or wall shower Then
connect the hot and cold lines from valves to diverter.
While supporting from below, carefully install and wrench
tighten the cartridge into the diverter body.
C. AFTER SOLDERING
Install the handle, and tighten the setscrew using a 3/32"
hex wrench.
Complete the installation and troubleshooting for the
valve, valve trim, and optional outlet according to the
instructions packed with them.
Confirm proper diverter operation.
A
1506311-2-
Deck/Rim
Or Wall
Brass Mounting
Nut
Side View
Diverter Valve
Body
NOTE: Provide Diverter Support
4
Escutcheon
Washer
Rubber Washer
Friction Washer
Fig. #7
Diverter
Fig. #8
Diverter Cartridge
Escutcheon
Deck/Rim
Or Wall
Fig. #9
Diverter Handle
Setscrew
Stem
Escutcheon