Charging the battery pack (see fig. A)
CAUTION!
Always unplug the appliance before you
remove the battery pack from or connect the
battery pack to the charger.
NOTE
Never charge the battery pack if the ambient
temperature is below 10°C or above 40°C.
If a lithium-ion battery is to be stored for an
extended period, the charge level should be
checked regularly. The optimum charge level is
between 50% and 80%. The storage climate
should be cool and dry and the ambient tem-
perature should be between 0°C and 50°C.
Connect the battery pack
battery charger
Insert the power plug into the socket. The green
charge control LED
red charge control LED
The green control LED
charging process is complete and the battery
pack
is ready.
CAUTION!
If the red control LED
that the battery pack
cannot be charged.
If the red and green control LEDs
flash, this means that the battery pack
broken.
Push the battery pack
Switch off the charger for at least 15 minutes be-
tween successive charging sessions. Also discon-
nect the power plug from the mains power socket.
PAP 20 B1 + PLG 20 C1
to the high-speed
(see fig. A).
lights up briefly, then the
lights up.
indicates that the
flashes, this means
has overheated and
both
into the appliance.

Checking the battery charge level

Press the battery charge level button
check the status of the battery (see also main
diagram).
The status/remaining charge will be shown on
the battery display LED
RED/ORANGE/GREEN = maximum charge
RED/ORANGE = medium charge
RED = low charge – charge the battery

Maintenance and storage

If you do not intend to use the appliance for
an extended period, remove the batteries and
store it in a clean, dry place away from direct
sunlight.
If a lithium-ion battery is to be stored for an
extended period, the charge level should be
checked regularly. The optimum charge level is
between 50% and 80%. The optimum storage
environment is cool and dry.
Never try to repair damaged batteries.
Maintenance of batteries should only be car-
ried out by the manufacturer or an approved
customer service centre.
is
to
as follows: