INSTRUCTION MANUAL
Introduction
The voltage tester 45216 is universally applicable tester for voltage testing, continuity
testing, rotary field testing and trip test of RCD.
The voltage tester 45216 is characterized by the following features
•
Designed to meet international safety standards IEC 61243-3:2014
•
Measurement category (CAT.) IV 600 V, III 1,000 V
•
AC and DC voltage test up to 1,000 V AC and 1,500 V DC
•
Polarity indication
•
Single-pole phase test
•
Phase rotation test
•
Trip test of RCD
•
Continuity test
•
Auto Power ON / OFF
•
Torch light
•
IP64 (IEC 60529)
•
Vibration motor
After unpacking, check that the instrument is undamaged.
The product package comprises
•
1x Tester 45216
•
2x 4 mm test tip adapters
•
2x CAT III/1,000 V test tip cover
•
2x Batteries 1.5 V (AAA, IEC LR03)
•
1x Instruction manual
Safety measures
The testers have been constructed and tested in accordance with the safety
regulations for voltage testers and have left the factory in a safe and perfect con-
dition. To maintain this condition, the user must observe the safety instructions
in this manual.
The operating instructions contain information and References required for
safe operation and use of the tester. Before using the tester, read the operating
instructions carefully and follow them in all respects.
Danger of electric shock and other dangers
To avoid an electric shock, observe the precautions when working with voltages
exceeding 120 V (60 V) DC or 50 V (25 V) eff AC. In accordance with DIN VDE
these values represent the threshold contact voltages (values in brackets refer to
limited ranges, e.g. in agricultural areas).
The tester must not be used with the battery compartment open.
Before using the tester, ensure that the test lead and device are in perfect wor-
king order. Look out e.g. for broken cables or leaking batteries.
Hold the tester and accessories by the designated grip areas only, the display
elements must not be covered. Never touch the test probes.
The tester may be used only within the specified measurement ranges and in
low-voltage installations up to 1,000 V AC / 1,500 V DC.
The tester may be used only in the measuring circuit category it has been
12