3. Technical data

General
Designation
Description
Measurement channel
Display
Keyboard
Measuring range
Resolution
Measurement Bandwidth
Signal amplification
Audio
Amplification
Maximum output
Headset
Headset connector
Power
Battery
Battery life
Environmental
Operating temperature
IP rating
Mechanical
Housing material
Dimensions instrument
Flexible rod length
Weight instrument
Carrying case dimensions
Total weight
(incl. case, sensor & 2 AA batteries)

4. Spare parts

Designation
TKSU 10-HEADS
TKSU 10-PROBE
TKSU 10-CC
SKF TKSU 10
Ultrasound leak detector
1 channel via a 7 pole LEMO connector
Color OLED
5 function keys
-6 to 99,9 dBµV (reference 0 dB = 1 µV)
0,1 dBµV
35 to 42 kHz
+30 to +102 by step of 6 dB
5 adjustable positions in steps of 6 dB
+83 dB SPL with supplied headset
25 dB NRR Peltor HQ headset
Stereo jack connector of 6,35 mm (
2 AA batteries
7 hours
From –10 °C to +50 °C (14 °F to 122 °F)
IP42
ABS
158 × 59 × 38,5 mm (6.22 × 2.32 × 1.51 in)
445 mm (17.51 in)
350 g (0.78 lb)
530 × 110 × 360 mm (20.9 × 4.3 × 14.2 in)
3 kg (6.6 lb)
Description
Neckband headset for TKSU 10
Spare airborne sensor for TKSU 10
Toolcase with inlay for TKSU 10