12<->24V
24V
b) Setting the performance level
After setting voltage protection (see previous paragraph), press
the "SLEEP" button for 1 second to select the performance
mode of the unit: HH (automatic) or ECO (energy saving - see
item 3.3.3 for details). The default setting is "HH". To change
the mode, select the appropriate one using the "UP" and
"DOWN" buttons. If no button is pressed for the next 5 seconds,
the device will save the currently selected mode.
c)
Selection of temperature scale units
After selecting the operating level, press the "SLEEP" button for
one second to select the temperature scale displayed –
Select the desired unit using the "UP" or "DOWN" buttons. If no
button is pressed for the next 5 seconds, the device will save
the currently selected value and return to the set operating
mode. However, if you press the "SLEEP" button again for 1
second, it will return to the setting of the option in subsection
a), then, b), c) and so on over and over again.
3.3.5
Tilt sensor/power cuts
The unit has a built-in tilt sensor that protects the unit from a drop
in performance and potential damage. If the operating unit is tilted
backwards (i.e. on the compressor side) more than 30
horizontal plane, the sensor will switch off the unit automatically. If
the sensor detects that the appliance has returned to the horizontal
position, the fridge will restart and operate with the preset
parameters.
H1
H2
H3
21.2
23.3
24.5
o
from its
23
25.3
26.2
C or F.
o