Thank you for choosing the HealthCraft Easy Mount Grab Bar. Please
read and understand the instructions in this manual; keep manual for
future reference. It is your responsibility to see that your Easy Mount Grab
Bar is properly installed, and cared for. Failure to follow instructions in this
manual could result in serious injury or death. If you are not equipped to
undertake the outlined work, we would recommend that you have your
HealthCraft Easy Mount Grab Bar installed by a qualified contractor.
The HealthCraft Easy Mount Grab Bar is intended for moderate vertical
and horizontal load bearing to provide sitting and standing support for
people with reduced mobility. The Easy Mount Grab Bar is installed with
appropriate fasteners to a structural wall. The maximum user weight for
this product is 500lbs / 227kg for bar lengths of 12", 18" and 24" and
400lbs / 181kg for lengths of 32", 36" and 42". Note: Product is not
intended to support full body weight. The Easy Mount Grab Bar is not to be
used in any other way than described above.
LIMITED LIFETIME WARRANTY
Products are covered by a limited lifetime warranty against defects in
materials and workmanship for the original purchaser. Warranty excludes
products that have been damaged through misuse, accidental damage,
alteration, normal wear and tear, wood material and stain, or the use of
corrosive or abrasive cleaning products.
Buyer hereby indemnifies, agrees to hold harmless and defend HealthCraft
Products Inc. from and against any and all liabilities, claims, (founded and
unfounded), losses, damages, costs and expenses (including without
limitation consequential damages and reasonable professional fees)
resulting from buyers specification, application, or improper use of goods
described hereon; buyers omission or neglect. HealthCraft Products Inc.
does not assume any liability for damage resulting from services performed
by others or faulty installation, misuse or misapplication of goods sold by
HealthCraft Products Inc. HealthCraft Products Inc. shall not be liable for
prospective profits or special, indirect, or consequential damages, or for the
cost of any corrective work done without HealthCraft Products Inc. prior
approval. HealthCraft Products Inc. total liability hereunder shall in no event
exceed the purchase price of the goods specified hereon. Specifications
subject to change without notice.
HealthCraft Products Inc.
2790 Fenton Road
Ottawa, Canada
K1T 3T7
English
Gate 88
Kanalgatan 45B
Skellefteå, Sweden
EC
REP
93123
DELIVERY CONTENTS / GRAB BAR
1. Grab Bar with Flange Covers
2. #10 x 2" Wood Screw, S/S (x6) (x8 for L/120 GB)
INSTALLATION WARNINGS
1. Rail must be installed to walls that are structurally sound.
2. If desired installation location does not have adequate structure, add
wood blocking.
3. CAUTION - Do not install if there is no structure behind drywall.
4. To reinforce hollow walls, we recommend Easy-Mount Anchors (each
sold separately). Weight capacity 300lbs.
5.Rail may be installed vertically to one stud.
6. Rail may be installed on an angle between 2 studs.
7. CAUTION - Do not install if structure behind walls is unknown.
8. CAUTION - Do not install into metal studs.
9. CAUTION - Do not install in fiberglass / acrylic shower enclosures with
insufficient stiffness and strength. 9b. Add wood blocking if required.
10. CAUTION - Rail and bathtub are slippery when wet.
SUGGESTED GRAB BAR LOCATIONS
To determine the optimal mounting location, we recomment holding the
rail in place and walking through the motions of a transfer (sitting,
standing, reaching ,etc.). Recommended horizontal rail height
33-36"/838-914mm. Recommened bar height for entering the shower is
48-60"/1219-1524 mm.

TECHNICAL DATA

See Figure D.
L SHAPED/120° GRAB BARS
1. Mark location of the corner flange fasteners.
2. Install fasteners, leave enough room for plate.
3. Lower the bar on the onto the fasteners. Continue installing by following
Figure F instructions.
INSTALLATION
1. Hold the rail against the wall and adjust with level. Using the flanges as
a locating guide, mark the screw hole locations.
2. Drill pilot holes for fasteners.
3. Fasten the rail to the wall using appropriate fasteners and
waterproofing.
4. Slide flange cover over flange to conceal screws. Inspect hardware
regularly, and tighten if required.