4 . 1 E X P E C T E D U S E
The Soho shampoo unit was conceived, designed and manufactured as a product for hairdressing
salons. This product can be used by ordinary people, as well as children over 8 years old, people
with reduced physical, sensory or mental capabilities and those with a lack of experience and
knowledge, provided they are supervised.
The maximum capacity is 130kg, and can only accommodate one person at a time.
ANY OTHER USE IS TO BE CONSIDERED IMPROPER, INCORRECT AND SOURCE OF
POTENTIAL DANGERS, INCLUDING THE PRODUCT'S USE IN WAITING AREAS OR
HOMES. THE MANUFACTURER DOES NOT ACCEPT RESPONSIBILITY IN CASE OF A USE
OF THE EQUIPMENT DIFFERENT FROM THE ONE IT WAS DESIGNED FOR.
4 . 2 S E R V I C I N G O F D O U B L E - I N S U L A T E D P R O D U C T S
In a double-insulated product, two systems of insulation are provided instead of earthing. No
earthing means is provided on a double-insulated product, nor is a means for earthing to be added
to the product.
Servicing a double-insulated product requires extreme care and knowledge of the system, and is to
be done only by qualified service personnel.
Replacement parts for a double-insulated product must be identical to the parts they replace.
A double-insulated product is usually marked with the words "DOUBLE INSULATION" or "DOUBLE
INSULATED", or will be marked with the symbol (square within a square)
4 . 3 L i f t i n g a n d t r a n s p o r t i n s t r u c t i o n s
Move the packed article with forklift or pallet. Remove the top and extract from cardboard box.
Perform the operation with 2 people.
4 . 4 T e c h n i c a l I n f o r m a t i o n
Standard characteristics
Maximum capacity
Supply voltage
Frequency
Power consumption
Dimensions
Mass
Sound pressure level in the workplace
4 . 5 S A F E T Y
Plug the machine into an easily accessible socket, checking that the net voltage ( V ) corresponds
to the machine's data plate.
• Avoid the use of extension cords. Plug directly into the electric socket whenever possible.
• Keep the power cable away from places where people walk to avoid it being crushed and so that
it does not form an obstacle or hindrance.
• To avoid dangerous electric shocks, use an electric socket equipped with a properly connected
socket-contact.
18
Use
.
U.D.M.
Value
Kg
130
V ~
100/220-240
Hz
50-60
W
43
Length mm
1230 - 1590
Depth mm
720
Height mm
980
Kg
62
Less than 70 dB(A)
4 . 6 e n v i r o n m e n t a l c h a r a c t e r i s t i c s r e q u i r e d
f o r s t o r a g e a n d u s e
The Soho shampoo unit must be stored with its original casing in an indoor area, away
from sources of heat, at a temperature between 10° and 40°C, with a moisture content
that does not exceed 70%. Once the casing is removed, the shampoo unit must
respect the same environmental characteristics, and must be located in areas with
illumination that respects the EN 12464-1 values.
We ask that you request support from your trusted installation company.

equipment DESCRIPTION

5 . 1 G e n e r a l d e s c r i p t i o n o f t h e e q u i p m e n t
The Soho wash unit model differs from the chairs normally used in hairdressing salons
thanks to the electric leg rest mechanism. Figure 1 shows the main components of the
Soho shampoo unit:
2
fig.1 main components of the Soho shampoo unit
1_Tilting ceramic basin, where hair is washed. It includes an anatomical ceramic
headrest, taps to mix warm and cold water and drainpipe to remove water.
2_Elevating leg rest.
EN