SOLUcIóN DE PRObLEMAS
100382-EU - 2600 PSI PRESSURE WASHER
SOLUcIóN DE PRObLEMAS
The usual cause of low pressure is as
follows:
Male and female hose adapters not
connecting properly.
Check connection between both male and female hose
adapters. Remove male from pump assembly and mate into
female and turn on water supply. If low or no pressure adapters
need to be replaced. It recommended that a brass female hose
adapter is used otherwise plastic and brass doesn't always
mate correctly.
blocked nozzles
Check for blockages in nozzles with needle or pin. (Refer to
manual)
Air lock in pump
ES
Disconnect 26ft outlet hose from pump, connect inlet water
supply and you should get a flow through the pump, start the
engine and repressurise the pump. Stop engine reconnect up
outlet hose and purge the air out of the gun by pressing the
trigger and repeat the start up process to regain pressure.
Damage or broken pressure spring
Remove 14mm bolt to first access the steel ball bearing, using
a magnet remove ball bearing and pressure spring, check and
replace spring if required. Put back together and retest washer
pressure. If problem persist then there may be an issue with the
pump or gearbox of the assembly. Contact us on +44 (0)1942
715407 option 2 for replacement parts.
Below is a illustration of where to find and check the pressure
spring: