Regular maintenance will extend the service life of your high-quality GESIPA
and they should be serviced at least every 2 years by an authorised workshop or by
GESIPA
Service. For tools that are used intensively, we recommend servicing ahead of
®
schedule.

1.10 Storage

The blind rivet setting tool should be stored in a dry place where there is no danger of frost.

1.11 Repairs

Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty
period should only be carried out by skilled technical personnel. Failure to observe the
assembly and setting procedures and operation by non-skilled personnel may result in seri-
ous damage to the blind rivet setting tool. In case of doubt, always send the blind rivet set-
ting tool back to the supplier or to GESIPA
You can find the current spare parts list for your tool online at www.gesipa.com.
Important! In the case of repairs not carried out by the manufacturer or where special ac-
cessories (e.g. extension units, angle heads) are used, it is mandatory to carry out a manual
reference run before using the tool again!
1.
Ensure that the tool is ready for operation and that all required attachments are correctly
mounted on it, then insert the battery.
2.
Turn LED ring to • zero position.
3.
Press and hold* the trigger button: the tool will move to the rear end position (riveting
tools) or drill briefly (blind riveting tools) and then stop.
4.
Turn LED ring to — Continuous light, without releasing the trigger button.
5.
Hold the trigger pressed for a further 10 seconds until the tool beeps 3x.
6.
The trigger button can now be released: the old reference values have been deleted.
7.
Pressing the trigger button* again starts the reference run; the tool will move forward and
back several times, flashing all the time.
*On tools with a spring-loaded trigger system, this must be pressed to release the tool.
After this reference run, start operation as described in section 1.6. Starting operation after a
repair without carrying out a manual reference run can result in serious damage to the riveting
tool.
.
®