Descargar Imprimir esta página

Troubleshooting; Blind Rivet Cannot Be Set; No Spent Mandrel Discharge; Led Lights Flashing - Gesipa AccuBird Pro AV Instrucciones De Manejo

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
GB
2.

Troubleshooting

2.1

Blind rivet cannot be set

Cause
No battery
Jaws dirty or worn
Jaw assembly loose
2.2

No spent mandrel discharge

Cause
Nosepiece too small
Dirt inside head
Spent mandrel container full
Mandrel tube blocked
2.3

LED lights flashing

Cause
No battery
Blind riveting tool overloaded
(LED flashes slowly – 1 Hz)
Blind riveting tool blocked on return
(LED flashes fast – 2 Hz)
3.

Warranty

The applicable terms and conditions of warranty shall apply and can be viewed under follow-
ing link: www.gesipa.com/agb
24
Remedy
Charge battery; replace if necessary
Clean them and lubricate or grease the sliding surfaces
or replace them (see 1.9)
Tighten (see 1.9)
Remedy
Exchange according to table (see 1.4)
Clean (see 1.9)
Take off and empty
Remove blocked mandrel and check for free ejection (see 1.9)
Remedy
Change battery (see 1.7)
Select rivet dimensions according to work
capacity (see 1.1; 1.7)
Unscrew steel head sleeve and remove
blockage (see 1.9)