06.
WATER SOFTENER INSTALLATION
Installation of this dishwasher is to be performed by authorized service and following the instructions
that the country's legislation.
Then follow the steps below for proper installation:
1. Check the water pressure of the network: it must be at least 2.5 bar and maximum 6 bar. Remember that
water temperature must be between 5 ° C and 40 ° C.
2. Before the installation, close the water tap usually the same place you are going to install and open a
faucet to depressurize it.
3. Choose an installation location near an electrical outlet of 220V - 50Hz
4. Check the correct status of the tubes.
5. Remove the cap covering the valve and then the lid of your softener. Remove the by-pass valve and the
transformer:
6. Connect the inlet and outlet to the "By-Pass".
3
1
2
7. Follow these steps to put the by-pass valve:
Remove the clips
Remove the threads
on the threads.
Input / Output.
8. Check the volumetric counter sensor is connected properly.
1. Input connection
2. Outlet connection
3. Drain connection
Place the boards
both threads.
SENSOR
1
1
2
Place the threads
in the valve.
2
1. Input connection
2. Outlet connection
Re-placing
Insert the By-pass
the clamps
in the valve.