9. Connect the valve to the transformer, and the transfor-
mer to the power supply cord:
10. Turn the valve by-pass by-pass position:
11. Connect the softener drain outlet to drain the network
where you are performing the installation. Never install the
drain line directly into a grid, sewer or sump. Always allow
an air gap between the drain line and the wastewater to
prevent it from being returned to the softener.
12. Also place a tube from the overflow outlet to drain (drain
line), to avoid possible flooding in the event of incorrect
programming, or a water leak by improper assembly, or a
valve failure. The level should be po drain below the outlet
to the overflow.
IMPORTANT: Do not connect the overflow outlet to the drain outlet of the valve. Could cause accidental
filling of the brine tank and cause flooding. So, install two separate tubes.
13. Fill The salt water until half of it. Then pour a bag of salt
approximately 25 Kg The salt (use only salt tablets for water
softeners special).
When filling the tank of salt, be careful not to rub salt e nel
protection tube cane brine.
14. Open the tap water and place the valve by-pass in
service position. Open a cold water tap nearby and let the
water run until air is removed from the softener.
Made depressurization, check the tightness of all connec-
tions. Let the water run for a few minutes to remove any
residues in the pipes.
By-pass
position
Air space
Drain
Maximum level
Middle level
Minimum level