OPERATING REQUIREMENTS

1. Typs:
Regularly check the equipment's clock matches the real time. In case of softening, it is recommended wash
and sanitize the resine once a month by products specially designed for softener maintenance.
Regularly check the softener performs a regeneration. Clean or replace the sediment filter (optional) perio-
dically. Use only special salt tablets for water softeners UNE 973. You should periodically observe the tank,
so that this will always remain with salt.
The recommended level of salt would be a little more than half of the tank.
Reset the program setting, after prolonged outages.
2. Clean or replace filter cartridges (not included. Sold separately):
1. Close the mains water.
2. Open a faucet to depressurize the network.
3. Close the by-pass in the filter.
4. Take out the vessel containing the cartridge.
5. If you have a filter cartridge wash it under a flow of water or replace it with a new one if required.
OPTIONAL: In case of siliphos cartridge replace it for a new one if the level of the balls is below the mini-
mum safety level.
It is advisable to perform the cleaning operation every time the filter cartridge turns a brown color. It
depends on the water in each area.
13.

TECHNICAL SERVICE

For the proper functioning of equipment should take into account these points periodically.
Perform periodically an analysis of mains and soft water.
Periodically clean and replace all gaskets and components in direct contact with water: filters, volumetric
meter, valve discs.
Inspect the system for signs of leakage or damage. All operations must be written down on the service
book.
Maintenance operations requiring removal of parts from the equipment, resulting in exposure to air parts,
which are in contact with water should be conducted under strict and hygienic control in order to avoid
system contamination. Staff should wear gloves and disinfect tools before use. Replaced parts shall be
properly disposed of and replacement parts must remain sealed in their containers until the last minute.