Descargar Imprimir esta página

Teka RMF 77810 GBK Manual Del Usuario página 16

Ocultar thumbs Ver también para RMF 77810 GBK:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
Temperature setting of freezing
chambers
Press temperature adjusting button of
the freezing chamber
the setting temperature of freezing
chamber and then each time a press of
temperature adjusting button of the
freezing chamber, the temperature will
be reduced 1°C.
The temperature setting range for
freezing chamber is -24°C ~ -16°C).
When the temperature is -24°C, press
the button again, and the temperature of
freezing chamber will be set at -16°C,
and it circulates again and again.
Mode setting
When super cool mode
temperature of refrigerating
chamber will automatically set at 2 °C.
Super cool exits for 6h;
Exit super cool mode
temperature of refrigerating chamber will
automatically return back to temperature
set before super cool mode.
When super freezing mode
temperature of freezing chamber will
automatically set at -24 °C.
Super freezing exits for 24h; Exit super
freezing mode
freezing chamber will automatically
return back to temperature set before
super freezing mode.
When vacation mode
temperature of freezing chamber will be
automatically set at -18°C; the
temperature of refrigerating chamber will
be automatically set at 5°C.
to change
is set,
mode,
is set,
, temperature of
is set,
Recommended setting: refrigerating
chamber 4°C, freezing chamber - 18°C.
NOTE
The quick-freezing function is designed to
maintain the nutritional value of the food in
the freezer. It can freeze the food in the
shortest time. If a large amount of food is
frozen at one time, it is recommended that the
user turn on the quick-freezing function and
put the food in. At this time, the freezing
speed of the freezer compartment is
increased, which can quickly freeze the food,
effectively lock the nutrition of the food, and
facilitate storage.
Storage upon power failure
In case of power failure, the instant
working state will be locked and
maintained till re-electrification.
Fault indication
The following warnings appearing on the
display indicate corresponding faults of
the refrigerator. Though the refrigerator
may still have cold storage function with
the following faults, the user shall
contact a maintenance specialist for
maintenance, so as to ensure optimized
operation of the appliance.
Fault
Code
E1
E2
E4
E5
E6
E7
EH
EN-15
Fault Description
Temperature sensor failure of
refrigerating chamber
Temperature sensor failure of freezing
chamber
Failure of defrosting sensor in
refrigerating chamber
Freezing defrost sensor detection circuit
error
Communication error
Circulation of temperature detection
circuit error
Moisture sensor error

Publicidad

loading