6. MAINTENANCE AND UPKEEP

6.1. Testing and cleaning

Please check and clean if necessary:
The main burner - if necessary, remove broken parts of stones and the existing dust.
Thermo-couple (if necessary, remove the existing sediment). In the event of visible damage contact your
dealer.
Glass screens – check for dirt smudges or possible scratches or cracks. If cracks are present replace the glass
screen for a new one. To conduct this contact your dealer.
Gas linkage and pressure regulator (in case their expiry date is invalid replace these ancillaries for new ones).
If you encountered problems with the regulator, gas linkage, burner or regulation valves do not try to fix these
parts. Contact a sales person, an authorised service or an importer in order to acquire spare parts. To ensure
the device is working efficiently use only original spare parts.

6.2. Glass cleaning

Most of the existing types of smudges may be wiped with a dry cloth. In case of more substantial smudge you may use
liquids normally applied to ceramic tiles or windows. Always dry the glass screen to avoid damp patches which could
irreversibly embed into the glass.
WARNING!!!
Avoid leaving fingerprints on the glass. They will be embedded into the glass and you will not be able to
clean them.
7.

TROUBLESHOOTING

Warning!
Montage, upkeep and service need to be conducted by a qualified professional with appropriate
qualification, an appropriate company or the gas supplier.
PROBLEM
SMELL OF GAS
Leak detected at cylinder,
regulator or other
connection.
Burner does not ignite
Igniter Not Working
Low efficiency, „cracking"
sounds
Thumping sounds made by
the regulator.
A vivid/ bright orange and
smoky flame of the burner.
POSSIBLE CAUSE
CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY. DO NOT USE THE
DEVICE UNTIL LEAKS HAVE BEEN REMOVED.
1. A loose regulator linkage.
2. Leak in the gas linkage, in the
regulator or on the gas knobs.
1. The bottle is empty.
2. Igniter linkage is not connected.
3. No ignition spark.
4. The igniter electrode is placed
incorrectly opposite the igniter.
5. Gas nozzles are blocked.
6. Gas linkage is twisted.
7. Pressure regulator link is loose.
1. Ignitor wire not connected.
2. Electrode misaligned on pilot burner
3. Igniter malfunction
4. The battery has run out
1. The bottle is empty.
2. The nozzles of the burner are
blocked.
The cylinder valve has opened rapidly.
Holes blocked in the apparatus
producing the gas and air mixture.
14
CORRECTIVE ACTION
1. Tighten and test it.
2. Report this issue to service.
1. Replace Gas Cylinder.
2. Connect the igniter linkage.
3. Replace igniter.
4. Realign electrode and clear any
surrounding debris from area.
5. Unmount burner, clean the nozzle.
6. Straighten the linkage. Keep the
linkage away from the housing.
7. Tighten the link. Check for leaks.
1. Ensure pilot electrode wire is
connected.
2. Realign electrode and clear any
surrounding debris from area.
3. Replace Igniter
4. Replace battery
1. Replace Gas Cylinder.
2. Unmount the burner, clean the
nozzle.
Unfasten the bottle valve slowly.
Unmount the burner and clean/ unblock
the apparatus' holes.

Publicidad