Descargar Imprimir esta página

Care Instructions - American Standard COLONY PRO 7074.400 Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

3
TEST INSTALLED FAUCET
• Remove AERATOR. With handles in OFF position, turn
on water supplies and check all connections for leaks.
• Operate both handles to flush water lines thoroughly.
Replace AERATOR.
4
SERVICE
CAUTION
If Faucet Drips, Proceed As Follows:
• Turn HANDLES to OFF position.
• If spout drips, operate HANDLES several times from OFF to ON position. Do not force HANDLES they turn only 90˚.
• AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and clean before reinstalling.
Change Handle Direction:
• Remove Plug BUTTON (1), loosen SET SCREW (2) and LIFT UP HANDLE (3).
• Remove Plastic Adapter (4) and cartridge nut (5).
• Lift and turn STOP WASHER 90˚.
• Re-install HANDLE components.
To Change Cartridge:
• Remove Plug BUTTON (1), loosen SET SCREW (2) and LIFT UP HANDLE (3).
• Remove Plastic Adapter (4) and cartridge nut (5).
• Lift CARTRIDGE (6) off Port (7).
• Clean CARTRIDGE (6) port.
• Place CARTRIDGE (6) onto Port (7) and tighten Cartridge Nut (5) alternately.
• Replace Plastic Adapter (4), HANDLE (3), tighten SET SCREW (2) and install INDEX BUTTON (1).
6

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Turn off hot and cold water
supplies before beginning.
Aerator
AERATOR
3
2
1
4
5
6
7
- 2 -
90°
90°
M965763 (9/16)

Publicidad