EN
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.7
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in an environmentally responsible way.
3
Description
3.1
Equipment
This is a double-acting hydraulic tool designed to be driven only by a Holmatro hydraulic pump. The
door opener is suitable only for opening doors in buildings.
3.1.1
Type designation
Example: DR 200 ST
/i
Digit
Example
1-2
DR
3-5
200
6-7
ST
3.2
Product identification
Refer to Fig. 2.
/i
1
Deadman's handle
2
Cylinder
3
Toe
3.3
Technical specifications
/i
Specifications
Allowable operating pressure
Maximum force
Maximum plunger stroke
Hydraulic oil net required volume
24
Description
DR = Door Ram
Type number
ST = Special Tactics - the colour is mainly black
Unit
bar / MPa
psi
kN / t
lbf
mm
in
cc
oz
916.400.194_003
4
Foot
5
CORE coupler (male)
6
Protection hood
DR200
720 / 72
71 / 7.2
DR200ST
10443
15961
300
11.8
265
9
DR200(ST)