TROUBLESHOOTING
PROBLEM
The air conditioner
does not corne on
The air conditioner
works for a short time
only
The air conditioner
works, but does not
cool the room
During operation,
there is an unplea­
sant smell in the
room
The air conditioner
does not operate for
about three minutes
after restarting it
The following message
appears on the display:
LI:./ P F / FI:.
CAUSE
• there is no current
• it is not plugged into the mains
• the internai safety device has
tripped
• here are bends in the air ex­
haust hose
• something is preventing the
air from being discharged
• windows, doors and/or cur­
tains open
• there are heat sources in the
room (oven, hairdryer, etc)
• the air exhaust hose is deta­
ched from the appliance
• the technical specification of
the appliance is not adequa­
te for the room in which it is
located.
• airfilter clogged
• the internai compresser safety
device prevents the applian­
ce from being restarted until
three minutes have elapsed
since it was last turned off.
• the appliance has a self dia
gnosis system to identify a
number of malfunctions.
• wait
• plug into the mains
• wait 30 minutes, if the problem
persists, contact your service can­
ter.
• position the air exhaust hose
correctly, keeping it as short
and free of curves as possible
to avoid bottlenecks
• check and remove any obsta­
cles obstructing air discharge
• close doors, windows and
curtains, bearing in mind the
"tips for correct use" given
above
• eliminate the heat sources
• fit the air exhaust hose in the
housing at the back of the
appliance (fig. 1 ).
• Clean the filter as discribed
Above.
• wait. This delay is part of nor­
mal operation.
• See the SELF-DIAGNOSIS
Chapter
72
SOLUTION

Publicidad

loading