Bonnet
Setscrew
Inner
Geared
Ring
Locking
Ring
4. Adjust the Maximum Water Temperature
Carefully pry the plug button off of the lever handle with a small
flat-blade screwdriver.
Loosen the setscrew, then remove the handle and bonnet.
Note the position of the locking ring relative to the inner geared
ring.
NOTE: To avoid damage to the locking ring during removal, pry
each side of the locking ring off the inner geared ring with an equal
and even technique.
Gradually pry each side of the locking ring up off of the inner
geared ring and onto the valve stem with a flat-blade screwdriver.
Rotate the locking ring clockwise to increase temperature, or
counterclockwise to decrease temperature.
Align the geared teeth, then slide the locking ring down until
flush against the inner geared ring.
Reinstall the bonnet and handle to the faucet body.
Test the temperature setting. Repeat the above steps, if needed.
Retighten the setscrew.
Press the plug button into place.