Descargar Imprimir esta página

Sagola V 4000 Manual De Instrucciones página 39

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
38/39
8 - Use the external regulator to obtain the appropriate atomisation. (No.2).
9 - Use the fan regulator (No.11) to obtain the required width.
3
DMM and QCM
Versions
Product filters (1.1.- Absorption filter 1.2.- Anti-pulse filter)
1
pressure regulation
Product pump
5
6
Spray pattern
9
10
10.2. Connect to air and assembly. DMR and QCR Versions
1 - Assemble the recirculating fitting or the cap.
2 - Connect recirculating to another spraygun or to the tank.
3 - Connect the product hose to the pressure pot or low pressure pump.
4 - Connect the air hose to a purifying regulator. (No.2).
5 - Connect an air hose to a 3-way valve (pilot). (No.11.1).
6 - Connect another air hose to a 3-way valve (Fan) (No.11.2).
7 - While the gun is spraying, operate the pressure pot regulator or pump (No.7), until the required
product is attained.
8 - The spraygun will begin to project product.
9 - Use the external air regulator (No.2) to obtain the appropriate atomisation.
10 - Use the filter group regulator (No.4) to obtain the desired fan width.
4
10
2
11
Filtering unit, pressure regulation of the gun drive
3
Pump pressure
Product pressure regulator
7
Spray gun product regulator
ENGLISH
7
1
2
6
9
Filtering unit and spray
2
8
Fan pattern regulator
11
5
8
1
1
Valve 3/2"
4
Product hose

Publicidad

loading