3.

Installation and Operation

3.1

Before Installing

Check before installing:
1. Drain hose with internal diameter not less than
35 mm.
2. Mains water feed connected to water purifier.
3. Stopcock with 3/8" G - male outlet.
4. Earthed plug protected with magnetic circuit
breaker.
5. Water feed from water purifier to machine
(supplied with the machine).
6. Drain hose (supplied with the machine).
7. Water purifier.

3.2 Installation

After unpacking the machine, take the following steps:
 Check that the mains voltage is the same as that on the specifications pla-
te and in the machine documentation.
1
Installing and Purging the Water Purifier
 Place the machine in the work area and con-
nect the ater supply to the water purifier filter
(2): with the stopcock (1) closed, connect the
short hose from the stopcock (1) to the filter
inlet (E) and connect the longer hose to the
filter outlet (S).
 Purge the water purifier outlet, opening the
stopcock and following the manufacturer's
instructions. Use a bucket or the installation
drainage to drain the water until it comes out
completely clean.
1
2
1
i
It is recommended adjusting the water
purifier until the water has a hardness
of between 5-8 dHº(8-14 fHº) to avoid
limescale and to achieve optimum pro-
duct quality.
4
E
S
2
22
1
5
6
2
2
Hydraulic connection and water supply
 Connect the water purifier filter outlet to the
pump inlet (3).
 Open the stopcock (1).
 Make sure the connections are tight and that
there are no water leaks.
3