14 Description of interface
Tab. 12
Commands/parameters – serial and Ethernet
Command r/w Authorization Reply
fmax x
L/s
I-all
s-Setter
foffs x
L/s
I-all
s-Setter
outp x
r/w
l-all
s-Setter
EWR 2 Net
copid x
r/w
l-all
s-Setter
copbd x
r/w
l-all
s-Setter
Ip w x y z r/w
l-all
s-Setter
nmask
r/w
l-all
w x y z
s-Setter
Gateway
r/w
l-all
w x y z
s-Setter
dhcpip x
r/w
l-all
s-Setter
tcpto x
r/w
l-all
s-Setter
Error messages
14.2 Commands/parameter – CANopen
Address
r/w Description
0x1002
r
Status register
0x2108sub1
r
Temperature
0x2109sub1
r
Input voltage
0x6400sub1
r
Operating mode
0x6401sub1
r
Incoming pressure
0x6402sub1
r
Outgoing pressure
0x6403sub1
r
Flow
0x6404sub1
r
Shunt current
0x6200sub1
r/w
Basic flow
0x6200sub2
r/w
Stagnation pressure
EN - 26
Description
fmax x
Basic flow
x = basic flow in I/min
foffs x
Flow offset at maximum x = offset flow in Nl/min
outp x
Outlet stagnation pressure
x = pressure in 1/10 bar
copid x
CANopen Node ID
x = CANopen Node ID
x = 0 ≙ 125 kBit/s
copbd x
CANopen baud rate (speed)
x = 1 ≙ 250 kBit/s
x = 2 ≙ 500 kBit/s
x = 3 ≙ 1000 kBit/s
Ip w x y z
IP address for TCP server.
A restart is required to adopt the IP.
nmask w x y z
Netmask for TCP server.
A restart is required to adopt the IP.
Gateway w x y z
Gateway for TCP server
A restart is required to adopt the IP.
dhcpip x
Change-over switch DHCP/static IP.
x = 1 DHCP
x = 0 static IP
tcpto x
Setting the TCP timeout. If no communication occurs
during this time, the TCP connection is disconnected.
Establishing connection again is required.
x = 0 off, no timeout
x = 1 to 10,000 timeout in ms
err 1
Unknown command
err 2
Number of arguments incorrect/authorization does
not exist.
err 3
Value range of arguments infringement.
Unit/explanation
Coded as Ethernet command "sys"
1/10 degrees Celsius
1/10 volts
0: Bypass, 1: Outlet pressure regulation, 2: volume flow regulation
1/10 bar
1/10 bar
1/10 l/min
% (of connected shunt value)
1/10 l/min
1/10 bar
EWR 2/EWR 2 Net
Value range
x = 2 to 23
x = 0 to 7
x = 2 to 20
x = 0 to 255
x = 0 to 3
w = 0 to 255
x = 0 to 255
y = 0 to 255
z = 0 to 255
w = 0 to 255
x = 0 to 255
y = 0 to 255
z = 0 to 255
w = 0 to 255
x = 0 to 255
y = 0 to 255
z = 0 to 255
x = 0 or 1
x = 0 to 10,000