TECHNICAL CUSTOMER SERVICE
Fig. 22
4. Disassembly of the basic board
Remove the cable harnesses which lead to the basic board. To disassemble the basic board,
unscrew the 5 T10 Torx screws (white arrows on fig. 24) and 2 hexagon head bolts (green
arrows on fig. 24).
The module can now be removed.
Fig. 24
To install, follow the instructions above in reverse.
5. Disassembly of the controller board
Some intermediate stages are necessary before the controller board can be disassembled.
Please note steps 1.1, 2 and 3 described above.
It is not necessary to carry out point 4.
5.1 Removing the support from the front frame.
Unscrew the 6 T20 Torx screws which connect the front frame and panel support (see white
arrows on fig. 25).
Fig. 23