9
Maintenance
10
Faults, causes and remedies
Fault
The control panel does not light
up
Pump does not start
Low water alarm
Short-circuit alarm
Low voltage alarm
11
Spare parts
12
Disposal
Installation and operating instructions Wilo-Isar BOOST5
Maintenance
Inspection and cleaning of non-return valve (Fig. 8)
ƒ
After lowering the system pressure, unscrew and remove the filler screw.
ƒ
Remove the non-return valve unit by unscrewing the fastening screw.
ƒ
Inspect and clean it.
ƒ
Reinstall the non-return valve unit. Make sure it is oriented correctly.
ƒ
Screw the filler screw back on properly.
Inspection and cleaning of non-return valve (Fig. 9)
ƒ
Lower the system pressure.
ƒ
Remove the cover and fork.
ƒ
Remove the bent connection.
ƒ
Extract the non-return valve.
ƒ
Check and clean it.
ƒ
Replace the non-return valve in its housing correctly.
ƒ
Reattach the bent connection, as well as the cover and fork.
WARNING
Risk of electric shock
Danger from electrical current must be eliminated. Ensure that the pump's power
supply is switched off and secured against unauthorised reactivation before per-
forming any electrical work.
LED signal
LEDs turned off
Red LED continuously lit
Flashing red LED
Green LED continuously lit
Flashing red LED, flashing green
LEDs in position 1
Flashing red LED, continuous
green LEDs in position 1.
Flashing red LED, flashing green
LEDs in position 5.
All spare parts should be ordered directly from the Wilo customer service. To prevent
errors, always quote the data on the pump's rating plate when making an order. The
spare parts catalogue is available at www.wilo.com
Information on the collection of used electrical and electronic products.
Remedy
Check that the side switch is set to "I".
Check the presence of mains power supply and conformity of
the residual-current device.
Switch on the pump by pressing the "I/O" button.
See the list of alarm codes in Section 8
System pressure does not fall below the set working pressure.
Check for water at the suction side.
Ensure the suction is not obstructed.
Fill and prime the pump.
Check the pump is not blocked by opening the plug at the back
of the motor and turning the shaft
Check that the cable, plug and socket are intact and there are
no leakages
Voltage is more than 15 % lower than value indicated on signal
plate. Stabilise voltage to keep it within the limits ±15%.
en
33