CAUTION
!
KEEP CLEAR OF NOZZLE: Do not exceed
maximum working pressure of 7500 PSI
(517 BAR, 51.7 Mpa).
PREVENTION:
NEVER Aim the gun at any part of the body.
NEVER Allow any part of the body to touch the
fluid stream. DO NOT allow body to touch a leak
in the fluid hose.
NEVER Put hand in front of the gun. Gloves will
not provide protection against an injection injury.
ALWAYS lock the gun trigger, shut the pump off,
and release all pressure before servicing, cleaning
the tip or guard, changing the tip, or leaving
unattended. Pressure will not be released by
turning off the motor. The PRIME/SPRAY valve
must be turned to PRIME to relieve the pressure.
Refer to the PRESSURE RELIEF PROCEDURE
described in the pump manual.
ALWAYS Keep the tip guard in place while
spraying. The tip guard provides some protection,
but is mainly a warning device.
ALWAYS Remove the spray tip before flushing
or cleaning the system.
ALWAYS inspect the hose before each use.
The paint hose can develop leaks from wear,
kinking, and abuse. A leak can inject material
into the skin.
NEVER Use a spray gun without a trigger lock
and trigger guard in place and in good working
order.
All accessories must be rated at 7500 PSI (517
BAR) or higher. This includes spray tips, guns,
extensions, and hose.
77-3084-R2.2 (7/2016)
BINKS AIRLESS 75M SPRAY GUN
5 / 14
NOTE
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury.
It is important to treat the injury as soon as
possible. DO NOT DELAY treatment to
research toxicity. Toxicity is a concern with
some coatings injected directly into the
blood stream. Consultation with a plastic
surgeon or reconstructive hand surgeon
may be advisable.
WARNING
!
HAZARD: EXPLOSION OR FIRE – Solvent
and paint fumes can explode or ignite.
Severe injury and/or property damage can
occur.
PREVENTION:
Provide extensive exhaust and fresh air
introduction to keep the air within the spray area
free from accumulation of flammable vapors.
Avoid all ignition sources such as static electricity
sparks, electrical appliances, flames, pilot lights,
hot objects, and sparks from connecting and
disconnecting power cords or working light
switches.
Do not smoke in spray area.
Fire extinguisher must be present and in good
working order. Place pump at least 25 feet
(7.6 m) away from the spray object in a well
ventilated area. Add more hose if necessary.
Flammable vapors are often heavier than air.
Floor area must be extremely well ventilated. The
pump may contain arcing parts that emit sparks
and can ignite vapors.
The equipment and objects in and around the
spray area must be properly grounded to prevent
static sparks.
Use only conductive or grounded high pressure
fluid hose. Gun must be grounded through hose
connections.
Power cords must be connected to a grounded
circuit.
Always flush unit into a separate metal container,
at low pump pressure, with spray tip removed.
EN