Descargar Imprimir esta página

Technical Data; Electrical Data Input 230 V; Standards 230V; Electrical Data Input 120 V - Fronius Acctiva Seller Manual De Instrucciones

Ocultar thumbs Ver también para Acctiva Seller:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63

Technical data

Electrical data
Mains voltage
input 230 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
Mark of conformity
EMC device class

Standards 230V

IEC 60068-2-6
IEC
60068-2-29
EN 60335-1
EN 61000-3-2
EN 61000-6-2
EN 61000-6-4
Electrical data
Mains voltage
input 120 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
Mark of conformity
EMC device class
60
Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; accelera-
tion 5 g)
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-2-29
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
(Class A)
~ 230 V AC ±15%
50/60 Hz
max. 2.9 A eff.
max. 16 A
max. 95%
max. 420 W
max. 1.7 W
I
none
CE
A
~ 120 V AC ±15%
50/60 Hz
max. 7.3 A eff.
max. 20 A
max. 93%
max. 420 W
max. 6.9 W
I
none
cTÜVus
A

Publicidad

loading