Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain
valve, for example a semi-pedestal.
• The drain valve may only be installed in basins with
an overflow opening.
• The mixer can not used together with a continuous
flow water heater.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
4
English
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Hansgrohe recommends not to use as drinking water
max. 1 MPa
the first half liter of water drawn in the morning or after
0,1 - 0,5 MPa
a prolonged period of non-use.
1,6 MPa
max. 60°C
70°C / 4 min
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 34)
Adjustment (see page 37)
Maintenance (see page 39)
Dimensions (see page 33)
Flow diagram (see page 33)
Normal spray
Regular
Spare parts (see page 40)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
700 = Matt White
Cleaning (see page 38)
Operation (see page 41)
Test certificate (see page 44)
Remedy
- Clean aerator, replace as
necessary
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter