Descargar Imprimir esta página

Greenlee 93-97/00220 Manual De Instrucciones página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

Diode Check
Do not connect the meter to a source of voltage or current when the
selector switch is in the
result.
1. Shut off and lock out the power. Make sure all capacitors are fully
discharged. Voltage must not be present.
2. Plug the black test lead into the COM terminal. Plug the red test lead into
the VΩ
terminal.
3. Set the selector switch to
4. Press
. The
5. Connect the test leads to the diode. The expected display for a diode in
good condition is approximately as follows:
Forward-Biased
Reverse-Biased
Note: A forward-biased reading of 000 (short circuit) or OL indicates that
the diode is faulty.
A reverse-biased reading of 000 (short circuit) or any numeric value
indicates that the diode is faulty.
All manuals and user guides at all-guides.com
position. Damage to the meter can
.
icon will appear.
Germanium-Based Diode
.025 volts - 0.45 volts
OL
93-97 / 00220
Silicon-Based Diode
0.40 volts - 0.90 volts
OL
13

Publicidad

loading