5. Clean up the debris and hairs.
6. Run water through the brush roll from a hose or spigot.
7. If your brush roll chamber is dirty, use the rag or towel to
clean it.
8. Allow the brush roll and chamber to dry before you
storing or picking up debris.
10.3
CLEAN THE PIPE
Turn off the machine before maintenance or troubleshooting
to reduce the risk of electric shock or injury.
1. Press the release button (8) to disconnect the extender and
floor brush.
2. Empty the collection bin.
3. Remove the brush roll.
4. Check the pipes of the vac, brush and extender.
NOTE
8
English
5. Pump the debris out or use the wire to clean the pipes if
pipes are blocked.
11
STORE THE MACHINE
Clean the machine before storage.
1. Remove the battery pack.
2. Let the motor cool.
3. Check that there are no loose or damaged components. If
it is necessary, replace the damaged components, tighten
screws and bolts, or speak to a person of an approved
service center.
4. Store the machine in a cool and dry location.
12
TROUBLESHOOTING
Problem
The machine
doesn't work.
Dust discharges
from exhaust.
Loss of suction
Static shock
Errors
11
NOTE
Possible cause
Solution
The switch or mo-
Speak to service
tor is defective.
center.
The filter has dam-
Replace the filter.
age.
The filter isn't in-
Properly reinstall
stalled.
the filter.
The filter is not
Clean or replace
functional.
the filter.
Clean or replace
The filter clogs.
the filter.
Clean or replace
The filter clogs.
the filter.
The collection bin
Empty the collec-
is full.
tion bin.
Add moisture to
The environment
air (if practical,
is dry.
use a humidifier).
EN