Descargar Imprimir esta página

The "Δ"- Lamp On The Control Panel Is On; Too Low Or Unstable Pressure - Ecolab Hybrid-P Manual De Servicio

Publicidad

6.2 The "Δ"- lamp on the control panel is on
6.3 If the inlet pressure is low or unstable
10
Check the display
for error
messages
Press "0" wait for a few
seconds and then
press "I" on the control
panel to restart the
system.
Does the error
Yes
come back
No
Start using the unit
again
Check the inlet
pressure is
between 2-8bar, at
maximum water
consumption
Is there sufficient
No
water supply?
Yes
Is the pump leaking
or making jarring
sounds?
Yes/no
Call a service
technician
Go to
softwaremanual
Is the filter
Yes
Clean the filter
Clogged
No
Secure higher inlet
pressure

Publicidad

Solución de problemas

loading

Este manual también es adecuado para:

Multi boosterBf16Bf24Bf32Bf40Bf48