10.3 Cleaning of the ventilation grill,
filter and condenser
In order for the unit to operate correctly, the
ventilation grill, filter and condenser must be
cleaned periodically.
A reminder for this periodic cleaning, to be
performed every 6 months, is provided through
sound alerts and a notification shown on the display.
The alert can be disabled and the time remaining
before the next cleaning viewed before it has to be
performed.
Behind the frontal ventilation grill (situated on the
lower part of the unit) is the condenser.
To clean it, use a Hoover with a soft brush
attachment at maximum power, sweeping it along
the vent slits. In the event of significant dust build
up, the ventilation grill can be removed to allow a
more thorough cleaning of the filter.
After the unit has been installed and turned on,
you can set the condenser cleaning warning in the
maintenance
settings.
Maintenance
Service
If the alert is enabled, it will sound every 6 months
Info System
to inform you that it is time to clean the condenser.
After cleaning it, touch the Reset icon to reactivate
the alert in another 6 months.
If you do not want the alert reminding you to clean
the condenser to sound any more, touch "Off".
To learn how to use the Maintenance display, see
function 9 in section 5.2.
See
the
instructions
in
section
11.2.
The lower condenser
To clean the condenser, follow these instructions:
> Switch off the appliance by pressing and holding
the Unit
button on the main control panel for
approx. 3 seconds.
> Wait approx. 30 minutes, until the condenser
cools down to room temperature.
> Remove the removable grill from under the door.
> Clean off any dust build-up completely, as shown
in the picture, taking care not to damage it.
> Restart the unit by once again pressing and
holding the Unit
button for three seconds.
Warning
The edges of the condenser are sharp,
therefore use suitable protection for
your hands and arms when cleaning the
condenser.
EN
79