Descargar Imprimir esta página

Configuration - Optimus UMX-LNK/E Manual De Instrucciones

Ocultar thumbs Ver también para UMX-LNK/E:

Publicidad

Idiomas disponibles

Idiomas disponibles

7) AUDIO LINK INPUT 2 SURVEILLANCE
Open collector output contact. Normally open contact. The
contact closes when a fault is detected in the cable
connection AUDIO LINK INPUT 2 (see figure 2).
8) Green LED. Shows the status of the AUDIO LINK INPUT 1
connection. LED ON indicates correct connection.
9) RJ45 connector AUDIO LINK INPUT 1.
The card constantly monitors this connection, turning ON the
yellow LED 10) and closing the contact 2) in case of fail or
disconnection.
Pin 1: CHANNEL 1 AUDIO INPUT HOT.
Pin 2: CHANNEL 1 AUDIO INPUT COLD.
Pin 3: CHANNEL 2 AUDIO INPUT HOT.
Pin 4: CHANNEL 3 AUDIO INPUT COLD.
Pin 5: CHANNEL 3 AUDIO INPUT HOT.
Pin 6: CHANNEL 2 AUDIO INPUT COLD.
Pin 7: INPUT SURVEILLANCE LINK 1.
Pin 8: GND.
*
Metal Shield
*
* In the AUDIO LINK INPUT 1 connector, the connection to the
chassis of the equipment is made through the Internal DIP Switch
5 and the connection between the shielding of the connector to
the GND is made through the internal DIP Switch 6.
10) Yellow LED. If it turns ON it indicates that the AUDIO LINK
INPUT 1 connection failed or was disconnected.

3. CONFIGURATION

Figure 3
UMX-LNK/E version 3.2.000 ENG
DIP Switch 5
GND
DIP Switch 6
UMX-LNK/E
11) Green LED. Shows the status of the AUDIO LINK INPUT 2
connection. LED ON indicates correct connection.
12) Conector RJ45 AUDIO LINK INPUT 2.
The card constantly monitors this connection, turning ON the
yellow LED 13) and showing an alarm through the PA
management software in case of fail or disconnection.
Pin 1: EMERGENCY CHANNEL AUDIO INPUT HOT.
Pin 2: EMERGENCY CHANNEL AUDIO INPUT COLD.
Pin 3: 24 VDC LINK (Degraded mode functionalities:
Through pin 3, the card is powered from the other
matrices, which guarantees its operation even in
the event that the matrix itself is not powered).
Pin 4: CHANNEL 4 AUDIO INPUT COLD.
Pin 5: CHANNEL 4 AUDIO INPUT HOT.
Pin 6: EMERGENCY PRIORITY INPUT CONTACT.
Pin 7: INPUT SURVEILLANCE LINK 2.
Pin 8: GND.
Metal Shield
* In the AUDIO LINK INPUT 2 connector, the connection to the
chassis of the equipment is made through the Internal DIP Switch
8 and the connection between the shielding of the connector to
the GND is made through the internal DIP Switch 7.
13) Yellow LED: If it turns ON it indicates that the AUDIO LINK
INPUT 2 connection failed or was disconnected.
DIP Switch 1: ON
DIP Switch 2: OFF
DIP Switch 3: ON
DIP Switch 4: OFF
DIP Switch 5: Connects the metal housing of the RJ45 INPUT 1 and
OUTPUT 1 connector to the chassis (factory default: ON)
DIP Switch 6: Connects the metal housing of the RJ45 INPUT 1 and
OUTPUT 1 connector to the GND (factory default: ON)
DIP Switch 7: Connects the metal housing of the RJ45 INPUT 2 and
OUTPUT 2 connector to the GND (factory default: ON)
DIP Switch 8: Connects the metal housing of the RJ45 INPUT 2 and
OUTPUT 2 connector to the chassis (factory default: ON)
Audio link card for slave matrix
COMPACT-E or UMX-03/0E
*
DIP Switch 8
GND
*
DIP Switch 7
6