2.0 - TECHNICAL DATA

• Use
• Ambient temperature (non-electric part)
• Ambient temperature (electric actuator)
• Surface temperature max
• Supply voltages (see table 2)
• Power supply tolerance
• Electric wiring
• Absorbed power
• Opening time
• Closing time
• Protection rating
• Class
• Mechanical resistance
• Rp Threaded connections
• Flanged connections to be coupled with PN 16 flanges : (DN 25*** - DN 32 - DN 40 - DN 50) ISO 7005 / EN 1092-1
• NPT threaded or ANSI 150 flanged connections : on request
• Filter element
• In compliance with
* See instruction sheet "Ex d electric actuator" (CPS19 .... - CPS25 ....).
** Only single-phase, the device does not work if powered with three-phase voltage.
*** DN 25 with swivel flanges.

2.1 - MODEL IDENTIFICATION

EV-1 EEX : Fast opening P. max 0.5 or 1 bar (see product label)
EVF-1 EEX : Fast opening + flow adjustment P. max 0.5 or 1 bar (see product label)

3.0 - COMMISSIONING THE DEVICE

3.1 - OPERATIONS PRIOR TO INSTALLATION

• It is necessary to close the gas upstream of the valve prior to installation;
• Make sure that the line pressure DOES NOT EXCEED the maximum pressure declared on the product label;
• Any protective caps (if any) must be removed prior to installation;
• Valve pipes and insides must be clear of any foreign bodies;
If the device is threaded:
• make sure that the pipe thread is not too long, to prevent damaging the body of the device when screwing it on;
If the device is flanged:
• make sure the inlet and outlet counter-flanges are perfectly coaxial and parallel in order to prevent unnecessary
mechanical stress to the body. Also calculate the space to insert the seal gasket;
• With regard to tightening operations, equip yourself with one or two calibrated torque wrenches or other controlled
locking tools;
Common procedures (threaded and flanged devices):
• In accordance with EN 161, a suitable filter must be installed upstream of a gas closing safety device;
EV(F)-1 EEX
: non-aggressive gases of the three families (dry gases)
: -20 ÷ +60 °C
: *
: *
: 24 Vdc - 24 V/50 Hz - 110 V/50-60 Hz - 230 V/50-60 Hz**
: -15% ... +10%
: *
: see table 2a - 2b
: <1 s
: <1 s
: IP66
: A
: Group 2
: (DN 15 - DN 20 - DN 25 - DN 32 - DN 40 - DN 50) according to EN 10226
: 1 mm mesh piping (only for DN 32 - DN 40 - DN 50)
: PED Directive 2014/68/EU (versions with P.max = 1 bar)
Direttiva ATEX 2014/34/UE - EMC Directive 2014/30/EU
LVD Directive 2014/35/EU - RoHS II Directive 2011/65/EU
10
Madas Technical Manual - 1|1.6a - REV. 0 of 10
Dec 2021