EN: Installation Sheet

Product Summary
NetworX Touchscreen keypad is an intuitive graphical touch
screen interface for users of the NetworX systems. It is offering
simple fingertip control of the security system with a clear 3.5"
touch screen with easy to understand graphics.
It can be customized for each location when it is installed. This
includes custom naming of zones, partitions, users and output
names. Users can even leave messages for other users via the
internal message centre.
Installation
1.
Loosen the bottom screw (see Figure 1.)
2.
Tilt the keypad from the bottom and remove it from the
wall bracket (see Figure 2.)
3.
Use the wall bracket as a template to mark where the bus
cable should feed through the wall (see Figure 3.)
4.
Drill appropriate holes and feed security cable through the
wall bracket.
5.
Screw the wall bracket to the mounting surface.
6.
Connect the bus cable to the back of the keypad (see
Figure 4.)
7.
Attach keypad to wall bracket by sliding the top of the
keypad onto the clips located on the top of the wall bracket
(see Figure 5.)
8.
Tighten the bottom screw to fix the keypad to the wall
bracket.
9.
Turn on power to security panel and program the keypad:
Zone names
Partition number
User names
Output names
Installer contact details
Room number (if intercom enabled)
Room names (if intercom enabled)
Specifications
Compatibility
All V2 series of NX-4, NX-6, NX-8, NX-8E
and complete range of NX-5, 7, 9, 10 ,11
series control panels
Operational voltage
12.0-13.5 VDC (provided by panel)
Current
170 mA max with sounder and screen on
max brightness,
40 mA in idle mode
Wire size
See Table 1 below.
Note: Additional two twisted pairs required
for intercom feature.
Dimensions (W × H × D)
95 mm x 155 mm x 68 mm
Operating temperature
0° to 49°C
range
(32° to 120°F)
Storage Temperature
−34° to 60°C
(−30° to 120°F)
Relative humidity
up to 90% noncondensing
2 / 10
Table 1: Maximum wire run
Length in
Wire gauge when
feet
connected to panel
250
24
500
20
1000
18
1500
16
2500
14
These numbers are for one keypad at the end of the wire.
When connecting more than one keypad to the end of the wire,
a higher gauge wire or a reduction in total wire distance will be
required. Star or daisy chain wiring configuration allowed.

Regulatory information

Placed on the market by:
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
This equipment has been tested and found to
FCC compliance
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
You are cautioned that any changes or modifications
not expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment.
Check local ordinances, this device is not listed by
NFPA 72
an approved test lab to meet NFPA 72 and therefore
may not be sold or installed for use with a fire
system in some localities.
EU compliance
UTC Fire & Security hereby declares that this device
European Union
is in compliance with the applicable requirements
directives
and provisions of one or more of the Directives
1999/5/EC, 2014/30/EU and 2014/35/EU. For more
information see: www.utcfireandsecurity.com or
www.interlogix.com
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
Customer support
For customer support, see www.interlogix.com/customer-
support or www.utcfssecurityproducts.eu
Wire gauge when
connected to remote PSU
22
18
16
14
12
P/N 230246 • REV D • ISS 26FEB15