Descargar Imprimir esta página

Aspes AG4600X Manual De Instrucciones página 16

Ocultar thumbs Ver también para AG4600X:

Publicidad

Idiomas disponibles

Idiomas disponibles

Positioning
6mm
3mm
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITH A COOKER HOOD ABOVE
700mm
400mm
This appliance is to be built into a kitchen unit or 600mm worktop, providing
the following minimum distances are allowed;
o
The edges of the hob must be a minimum distance of 60 mm from a side or
rear wall.
o
700 mm between the highest point of the hob surface (including the burners)
and the underside of any horizontal surface directly above it.
o
400 mm between the hob surfaces, providing that the underside of the
horizontal surface is in line with the outer edge of the hob. If the underside of
the horizontal surface is lower than 400 mm, then it must be at least 50 mm
away from the outer edges of the hob.
o
50 mm clearance around the appliance and between the hob surface and any
combustible materials.
o
You must have a gap of at least 25 mm and at most 74 mm between the
underneath of the appliance and any surface that is below it.
- An oven must have forced ventilation to install a hob above it.
- Check the dimensions of the oven in the installation manual.
- The cut out size must obey the indication.
3mm
AG4600X
400mm
25mm(MIN)
15
Model
X
560
45mm
Y
Z
480
600

Publicidad